Analysis on the performance parameters of marine ejector refrigeration rotary desiccant air-conditioning driven by waste heat

ZHENG Chao-yu, ZHENG Qing-rong, CHEN Wu

Journal of Dalian Maritime University ›› 2020, Vol. 46 ›› Issue (4) : 95-101.

PDF(911 KB)
PDF(911 KB)
Journal of Dalian Maritime University ›› 2020, Vol. 46 ›› Issue (4) : 95-101. DOI: 10.16411/j.cnki.issn1006-7736.2020.04.012

Analysis on the performance parameters of marine ejector refrigeration rotary desiccant air-conditioning driven by waste heat

  • ZHENG Chao-yu1, ZHENG Qing-rong1, CHEN Wu*2
Author information +
History +

Abstract

 In order to study the energy saving characteristics of the ejector refrigeration rotary desiccant air-conditioning system driven by waste heat in ships, combining with the design parameters of a real marine air-conditioning system, the steam consumption, power consumption and COP of the system were calculated and analyzed under different entrainment ratio conditions, and compared with the traditional marine air-conditioning system. The results show that when the entrainment ratio is in the range of 0.1~0.9, the steam consumption decreases from 2851.1kg/h to 804.2kg/h, the power consumption decreases from 52.54kW to 35.83kW, and the COP increases from 6.34 to 9.29, which can achieve 59.33%~72.27% energy saving effect. However, most of the contribution to the reduction of steam consumption and power consumption is achieved when the entrainment ratio is low, and the contribution of entrainment ratio from 0.1 to 0.2~0.3 accounts for 56.25%~75%, while the contribution of entrainment ratio from 0.3 to 0.9 only accounts for 25%. It can be seen that the marine ejector refrigeration rotary desiccant air-conditioning has good energy saving potential, but when the entrainment ratio increases to 0.2~0.3, the effect of further increasing the entrainment ratio on energy saving and consumption reduction is not obvious. Therefore, in construction of the system, it should be considered comprehensively, and there is no need to use too high entrainment ratio. This study provides a reference for the application of ejector refrigeration rotary desiccant air-conditioning system in ships.

Key words

marine air-conditioning / ejector refrigeration / rotary desiccant / waste heat / energy saving / performance parameters

Cite this article

Download Citations
ZHENG Chao-yu, ZHENG Qing-rong, CHEN Wu. Analysis on the performance parameters of marine ejector refrigeration rotary desiccant air-conditioning driven by waste heat[J]. Journal of Dalian Maritime University. 2020, 46(4): 95-101 https://doi.org/10.16411/j.cnki.issn1006-7736.2020.04.012

References

[1]Marine Environment Protection Committee.Initial IMO strategy on reduction of GHG emissions from ships[S]. 2018.
[2]胡琼, 周伟新, 刁峰.IMO船舶温室气体减排初步战略解读[J].中国造船, 2019, 60(1):195-201
[3]甘念重.船舶主机热平衡分析及其余热利用[J].船海工程, 2008, 37(2):66-69
[4] S. Lion, I. Vlaskos, R. Taccani..A review of emissions reduction technologies for low and medium speed marine Diesel engines and their potential for waste heat recovery[J].Energy Conversion and Management, 2020, 207:112553-
[5] G.Q. Shu, Y.C.Liang, H.Q. Wei, H. Tian, J. Zhao, L. Liu. .A review of waste heat recovery on two-stroke IC engine aboard ships[J].Renewable and Sustainable Energy Reviews, 2013, (19):385-401
[6]董景明, 潘新祥, 宋立国.喷射式制冷在船舶空调中的应用研究[J].船舶工程, 2011, 33(1):29-32
[7]智会杰, 郑青榕.船用锅¯蒸汽余热吸附式空调的试验研究[J].中国造船, 2012, 53(2):156-161
[8]郑超瑜, 陈武.船用除湿蒸发冷却空调系统显热处理方式研究[J].船舶工程, 2013, 35(2):47-50
[9] 刘晓华, 江亿.温湿度独立控制空调系统[M]. 北京, 中国建筑工业出版社, 2006.
[10] T. Zhang, X.H. Liu, Y. Jiang..Development of temperature and humidity independent control(THIC) air-conditioning systems in China-A review[J].Renewable and Sustainable Energy Reviews, 2014, (29):793-803
[11] X.G. Xu, Z.W. Zhong, S.M. Deng, X.B. Zhang.. A review on temperature and humidity control methods focusing on air-conditioning equipment and control algorithms applied in small-to-medium-sized buildings[J].Energy and Buildings, 2018, (162):163-176
[12]G.J. Zheng,CY. Zheng,G.H. Yang,W. Chen. Development of a new marine rotary desiccant air-conditioning system and its energy consumption analysis[J].Energy Procedia, 2012, 16(part B):1095-1101
[13] J. Zhu, W. Chen. .Energy and exergy performance analysis of a marine rotary desiccant air conditioning system based on orthogonal experiment[J].Energy, 2014, (77):953-962
[14] J. Zhu, W. Chen.. A novel multivariate linear prediction model for the marine rotary desiccant air conditioning by adding a dynamic correction factor[J].Applied Thermal Engineering, 2015, (78):101-109
[15] 郑超瑜, 俞文胜, 陈武.船用蒸汽喷射制冷-转轮除湿空调系统构架研究[C]. 2016 年第九届全国制冷空调新技术研讨会论文集, 文章编号: 186.
[16] C.Y. Zheng, C.X. Zhao, W. Chen. .A novel marine ejector-refrigeration rotary-desiccant air-conditioning system and its working fluid analysis[C]. 25th IIR International Congress of Refrigeration, Montreal, Canada, 2019, pp. 2061-2068.
PDF(911 KB)

Accesses

Citation

Detail

Sections
Recommended

/