A correction method of the seismic  input by considering embedment effect

LIU Jin-chao,QU Xian-qing

Journal of Dalian Maritime University ›› 2013, Vol. 39 ›› Issue (3) : 107-111.

PDF(567 KB)
PDF(567 KB)
Journal of Dalian Maritime University ›› 2013, Vol. 39 ›› Issue (3) : 107-111.
Original Paper

A correction method of the seismic  input by considering embedment effect

  • LIU Jin-chao1, QU Xian-qiang2
Author information +
History +

Abstract

Considering the actual structural design of a nuclear power’s plant pump house, the semiembeded characteristics and their limitations resulting from empirical formula method and numerical analysis method are respectively studied. The paper points out that the seismic inputs of bedrock surface which directly adopted to calculate the half buried structure are often too large. Therefore, a correction method of earthquake input for the semiembeded structures is presented. The seismic’s displacement and velocity of the artificial border soil node need to be known for this method. The velocity and displacement time course curves of the depth underlying soil are obtained by integrating seismic acceleration time.

Key words

nuclear power engineering / pump house / semi-buried structure / seismic design / correction method

Cite this article

Download Citations
LIU Jin-chao,QU Xian-qing. A correction method of the seismic  input by considering embedment effect[J]. Journal of Dalian Maritime University. 2013, 39(3): 107-111

References

[1] 廖振鹏. 工程波动理论导论[M]. 北京: 科学出版社, 2002. LIAO Zhen-peng. Introduction to engineering wave theory[M]. Beijing: Science Press, 2002.(in Chinese) [2] St JOHN C M, ZAHRAH T F. A seismic design of underground structures [J]. Tunnelling and Underground Space Technology, 1987, 2: 165-197. [3]郑永来. 地下结构抗震[M]. 上海: 同济大学出版社, 2005. ZHENG Yong-lai. Anseismic of underground structure[M]. Shanghai: Tongji University Press, 2005.(in Chinese) [4]MADDALONI1 G, MAGLIULO G, COSENZA E. Effect of the seismic input on nonlinear response of R/C building structures[J]. Adv Struct Eng, 2012(10): 1861-1877. [5] TOMASSOLI E, MEZZI M. Energy-based criterion for the selection of the seismic input for inelastic dynamic analyses[C]// 9th US National and 10th Canadian Conference on Earthquake Engineering,2010(7): 2338-2347. [6] FU J, KEN J. Seismic performance evaluation of existing R/C asymmetric buildings considering the direction of seismic input[J]. Journal of Structural and Construction Engineering, 2012(4): 565-574. [7] MA H , LIU C Y , LI Z B , et al. The influence of seismic input in the oblique direction on the strongcolumn weakbeam mechanism for RC frame[J]. Adv Mater Res, 2011(6): 5144-5155. [8] CILINGIR U. A model study on the effects of input motion on the seismic behaviour of tunnels[J]. Soil Dyn Earthqu Eng, 2011(3): 452-462. [9] DEEKS A J, RANDOLPH M F. Axisymmetric timedomain transmitting boundaries[J]. Journal of Engineering Mechanics, ASCE, 1994, 120(1): 25-42. [10] 胡聿贤, 张裕明. 中华人民共和国国家标准——工程场地地震安全性评价(GB 17742005)[S]. 北京:中国国家标准化管理委员会, 2005. HU Yu-xian, ZHANG Yu-ming. National standards of the People’s Republic of China seismic safety evaluation of engineering site(GB 17741-2005)[S].Beijing: China National Standardization Management Committee, 2005.(in Chinese)
PDF(567 KB)

Accesses

Citation

Detail

Sections
Recommended

/